Prüfmittel Verpackungen
j5soq1

Steinfurth Rotation Tester für Sport Verschlüsse

Sicherheitsprüfung von Sportverschlüssen

  • Rotation Tester
  • Rotation Tester
  • Rotation Tester
  • Rotation Tester
  • Rotation Tester
  • Rotation Tester
  • SCRT
  • SCRT
  • Rotation Tester
  • Rotation Tester

Für dieses Produkt existiert zur Zeit nur eine englische Produktbeschreibung:

The Rotation Tester for Sport Closures (RTSC) is an appliance designed for use on an automatic tensile testing machine.
It consists of a preform fixture mounted to a wheel, a bite mechanism with integrated adjustment fixture and a safety coupling.
The purpose of this device is the simulation of a human attempting to open the spout cap of a sports closure, especially with his or her teeth.
The design of the clamp assembly complies with ISBT physical performance testing methods #102 and #103. It simulates a human (infant) jaw with teeth.
The bite force is set by shifting a weight along a threaded rod. It can be measured using a standard load cell. With the specimen preform with closure in place, the closure is rotated around the position of the clamped spout, possibly resulting in completely removing or damaging the spout cap.

The Rotation Tester for Sport Closures (RTSC) is an appliance designed for use on an automatic tensile testing machine. It consists of a preform fixture mounted to a wheel, a bite mechanism with integrated adjustment fixture and a safety coupling.
The purpose of this device is the simulation of a human attempting to open the spout cap of a sports closure, especially with his or her teeth.  

Als PDF ausgeben
Produktdetails Spezifikation
Branche Getränke, Verpackung
Anwendung Sicherheitsüberprüfung
Messgrößen
Objekte Sportverschlüsse
Besonderheiten Standardisierter Teststand
System Nein
Automatisierungsgrad
Messmethoden Physical Performance Test Method for Sport Closures - Bite Test, Physical Performance Test Method for Sport Closures - Rotational Test
  • Bite force (max.): 141 N / 31.7 lbf
  • Specimen diameter between jaws (bottom end): 30 mm / 1.2 in
  • Specimen diameter in preform clamp (top end): 15...27 mm / 0.6..1.2 in
  • Supply pressure: 7.5...10 bar / 110..145 psi
  • Dimensions of applicable load cell (h x w x l): 64 mm x 13 mm x 51 mm or 2.5 in x 1/2 in x 2 in
  • Suitable screws for load cell: DIN EN ISO 4762 – M6 x 20 or Hex socket head screw UNC 1/4” x 3/4 in
  • Load cell capacity: 200 N / 45 lbf  

Steinfurth Rotation Tester für Sport Verschlüsse

Diese Website nutzt Cookies. Um alle Funktionalität der Website zu nutzen, stimmen Sie bitte der Verwendung von Cookies zu. Mehr Informationen zum Datenschutz finden Sie hier.
Ich stimme zu